Description
SICK LFP2000-G1NMB 1052085
Product Summary
HYGIENIC LEVEL PROBE
Manufacturer: Sick
Manufacturer part number: 1052085
SKU: 185384
Weight(kg): 2.8450
-
- Level monitoring in hygienic applications
- Manually cutable monoprobe made from stainless steel 1.4404 up to 2,000 mm long with Ra ≤ 0.8 µm
- Process temperature up to 150 °C, process pressure up to 16 bar
- CIP/SIP resistant
- IP 67 and IP 69K enclosure rating
- Interchangeable hygienic process connections
- 3-in-1: combined display, analog output and binary output
- Analog output 4 mA … 20 mA / 0 V … 10 V, switchable, plus two binary outputs
Your benefits
- Robust design increases service life
- High flexibility due to cutable probe and interchangeable connection concept
- Cost savings due to multiple output signals: one system for both level detection and continuous level monitoring
- Time and cost savings due to low maintenance and quick commissioning
- No calibration or recalibration required for commissioning, thus saving time and costs
Features
| Medium: | Fluids |
| Measurement: | Switch, Continuous |
| Probe length: | 2,000 mm |
| Process pressure: | -1 bar … 16 bar |
| Process temperature: | -20 °C … 150 °C |
| EHEDG approval: | ![]() |
| GOST approval: | ![]() |
| RoHS certificate: | ![]() |
| IO-Link: | ![]() |
| 3-A: | 0 |
| Performance | |
| Resolution: | < 2 mm |
| Accuracy of sensor element: | ± 5 mm |
| Repeatability: | ≤ 2 mm |
| Dielectricity constant: | ≥ 5 |
| Inactive area at process connector: | 25 mm 1) |
| Inactive area at probe end: | 10 mm 2) |
| Conductivity: | No limitation |
| Response time: | < 400 ms |
| 1) With parameterized tank with water under reference conditions, otherwise 40 mm 2) With water under reference conditions | |
| Mechanical data | |
| Housing material: | 303 |
| Max.probe load: | 6 Nm |
| Process connection: | G ¾ A |
| Wetted parts: | 316L (Ra ≤ 0,8 µm), PEEK |
| Housing design: | With PMMA viewing window |
| Electrical data | |
| Temperature drift: | < 0.1 mm/K |
| Enclosure rating: | IP 67: EN 60529, IP 69K: EN 40050 |
| Supply voltage: | 12 V DC … 30 V DC 1) |
| Power consumption: | ≤ 75 mA at 24 V DC without output load |
| Protection class: | III |
| Initialization time: | ≤ 2 s |
| Output load: | 0 V … 10 V > 750 Ohm at Uv >= 14 V, 4 mA … 20 mA < 400 Ohm at Uv > 12 V, 4 mA … 20 mA < 500 Ohm at Uv > 13,5 V |
| Upper signal level: | 20 mA … 20.5 mA |
| Lower signal level: | 3.8 mA … 4 mA |
| Hysteresis: | Min. 2 mm, free adjustable |
| Output current: | < 100 mA |
| Signal voltage HIGH: | Vs – 2 V |
| Signal voltage LOW: | ≤ 2 V |
| Capacitive load: | 100 nF |
| Inductive load: | < 1 H |
| Connection type: | Round connector M12 x 1, 5-pin |
| EMC: | EN 61326-1:2006, 2004/108/EG |
| Interference resistance: | EN 61000-6-2:2005 |
| Interference emission: | EN 61000-6-4:2007 |
| Single- and continuous shock: | EN 60068-2-27 |
| 1) All connections are polarity protected. All outputs are overload and short-circuit protected. | |
| Ambient data | |
| Ambient operating temperature: | -20 °C … 60 °C |
| Ambient storage temperature: | -40 °C … 80 °C |
Products specifications
| Manufacturer category | Sick LFP |
| Manufacturer | Sick |






Reviews